What was found
DURING HEAVY MAINTENANCE VISIT, FOUND THE FLOOR SUPPORT CHANNEL AT STATION 344, RBL 50 - 62.5 CORRODED OUT OF LIMITS. REMOVED, FABRICATED, AND INSTALLED NEW CHANNEL IAW SRM 51-30-2, 51-20-2, 51-10-1 AND DRAWING 65-26173.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE VISIT, FOUND THE FLOOR SUPPORT CHANNEL AT STATION 344, RBL 50 - 62.5 CORRODED OUT OF LIMITS. REMOVED, FABRICATED, AND INSTALLED NEW CHANNEL IAW SRM 51-30-2, 51-20-2, 51-10-1 AND DRAWING 65-26173.