What was found
DURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON THE RIGHT TUNNEL 186 END AT FLOOR SUPPORT BEAM END IN THE WASTE TANK COMPARTMENT, APPROXIMATELY STATION 2007, FLOOR LEVEL. REMOVED CORRODED SECTION AND SPLICED IN A REPAIR IN ACCORDANCE WITH SRM 53-70-00, FIGURE 13 AND SRM 51-31-01.