What was found
DURING A HEAVY MAINT CHECK, CORROSION WAS FOUND AT STATION 1110 ON T-CAP OF FLOORBEAM AT BL 0. CORROSION WAS TO BE OUT OF LIMITS IAW B727 SRM 511001. CUT OUT DAMAGED AREA IAW B727 SRM 531008. FABRICATED UPPER CHORD FROM BAC 1505100617. FABRICATED NEW SUPPORT ANGLES FROM BAC 14902785. FABRICATED SUPPORT ANGLES FROM BAC 14902831. FABRICATED REINFORCEMENT STRAP FROM 7075 T6 .080. FABRICATED REINFORCEMENT STRAP FROM 7075 T6 .051. TREATED AND PRIMED IAW B727 SRM 511001 MM 512002. INSTALLED IAW B727 SRM 513002.