As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A HEAVY MAINT CHECK CORROSION WAS FOUND ON T-CAP OF FLOORBEAM AT STATION 1130 RBL 5 AFT CARGO PIT CEILING. CORROSION WAS FOUND TO BE OUT OF LIMITS IAW B727 SRM 531001. REMOVED DAMAGED AREA IAW B727 SRM 513002. FABRICATED NEW PART FORM BAC14902831 IAW B727 SRM 531008. TREATED AND PRIMED IAW B727 SRM 511002. INSTALLED IAW B727 SRM 513002.