What was found
DURING A HEAVY MAINTENANCE CHECK, THE FLOORBEAM STABILIZER STRAP WAS FOUND CRACKED AT LBL 24 75 FORWARD OF THE FLOORBEAM AT BS 360. REMOVED DAMAGED AREA AND FABRICATED REPAIR PART AND INSTALLED IAW SRM 53108 FIG 6.