What was found
DURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS ON LONGITUDINAL FLOORBOARD SUPPORT ANGLE, FS 1050 LBL 15. REMOVED CORROSION IAW SRM 511006. REMOVED FLOORBOARD SUPPORT IAW B727 SRM 513002. FABRICATED NEW FLOORBOARD SUPPORT FROM BAC 15064417 PER SAMPLE. TREATED IAW B727 SRM 511002. PRIMED IAW B727 MM 512002. INSTALLED IAW B727 SRM 513002.