What was found
DURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS AT FORWARD PIT RIGHT STRINGER, BETWEEN 26 AND 27 SHEAR TIE AT BS 720E. REMOVED CORROSION IAW SRM 511006. REMOVED CORRODED SHEAR TIE IAW SRM 513002. FABRICATED SHEAR TIE FROM ALC 2024 T3 PER SAMPLE. TREATED AND PRIMED IAW 511002 AND MM 512002.