What was found
SAW - DURING CPCP-2 INSPECTION, FOUND FLOOR SUPPORT BETWEEN FRAMES 36R AND 38R CORRODED BEYOND LIMITS. REMOVED AND REPLACED FLOOR CHANNEL IAW SRM 51-25-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SAW - DURING CPCP-2 INSPECTION, FOUND FLOOR SUPPORT BETWEEN FRAMES 36R AND 38R CORRODED BEYOND LIMITS. REMOVED AND REPLACED FLOOR CHANNEL IAW SRM 51-25-01. (M)