What was found
ABI - DURING MBV INSPECTION, FOUND CENTER BEAM GUSSET CORRODED AND CHAFED. REMOVED AND REPLACED GALLEY CENTER BEAM GUSSET IAW EMB 145 SRM 51-40-22. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ABI - DURING MBV INSPECTION, FOUND CENTER BEAM GUSSET CORRODED AND CHAFED. REMOVED AND REPLACED GALLEY CENTER BEAM GUSSET IAW EMB 145 SRM 51-40-22. (M)