What was found
ABI - DURING MBV INSPECTION, FOUND CENTER BEAM AT FRAME 21 CORRODED. REPAIRED CENTER BEAM AT FRAME 21 IAW EMB REPAIR STATEMENT GST-3196/01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ABI - DURING MBV INSPECTION, FOUND CENTER BEAM AT FRAME 21 CORRODED. REPAIRED CENTER BEAM AT FRAME 21 IAW EMB REPAIR STATEMENT GST-3196/01. (M)