As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ABI - DURING A MBV, FOUND CORROSION ON THE GALLEY CENTER OMEGA BEAM. REMOVED CORROSION BY BLENDING OUT. PERFORMED AN NDT INSPECTION ON THE AREA WITH NO REJECTABLE INDICATIONS. FABRICATED A 'Z' REPAIR DOUBLER. REPAIR DONE IAW EMB GST-3598/01 PARA 7 AND STANDARD SRM PRACTICES. (M)