What was found
ABI - DURING MBV INSPECTION MAINTENANCE, FOUND THE BOLT HOLES ON THE L SHAPED FLOOR EXTENSION TO BE CORRODED AT FRAME 22. MAINTENANCE REPLACED THE FLOOR EXTENSION AT FRAME 22 IAW EMB 135 SRM 51-20-01 AND 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ABI - DURING MBV INSPECTION MAINTENANCE, FOUND THE BOLT HOLES ON THE L SHAPED FLOOR EXTENSION TO BE CORRODED AT FRAME 22. MAINTENANCE REPLACED THE FLOOR EXTENSION AT FRAME 22 IAW EMB 135 SRM 51-20-01 AND 51-40-02. (M)