What was found
ABI - DURING MBV INSPECTION MAINTENANCE, FOUND CORROSION ON THE FLOORBOARD SUPPORT ANGLE ON THE LEFT OMEGA BEAM AT FRAME 20. MAINTENANCE REPLACED THE FLOORBOARD SUPPORT ANGLE ON THE LEFT OMEGA BEAM IAW EMB SRM 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ABI - DURING MBV INSPECTION MAINTENANCE, FOUND CORROSION ON THE FLOORBOARD SUPPORT ANGLE ON THE LEFT OMEGA BEAM AT FRAME 20. MAINTENANCE REPLACED THE FLOORBOARD SUPPORT ANGLE ON THE LEFT OMEGA BEAM IAW EMB SRM 51-40-02. (M)