What was found
ABI - DURING AN IMBV INSPECTION, FOUND THE LEFT OMEGA BEAM AT FRAME 20 CORRODED BELOW SRM LIMITS. CUT OUT SECTION OF LEFT OMEGA BEAM. FABRICATED A FILLER, SHIMS, BACK PLATE AND EXTERNAL ANGLE. REPAIR DONE IAW EMB 145 SRM (145/1142 REV 19) CHAPTER 53-21-10 FIG 201. (M)