ABI - THIS IS A LEVEL 2 FINDING. CENTER BEAM GUSSET REMOVED CORROSION FOUND ON CENTER BEAM AT FRAME 20. CUT OUT DAMAGED AREA AND REPAIRED IAW EMB135 SRM 53-21-10. (M)