What was found
ABI - THIS IS A LEVEL 2 FINDING. CENTER BEAM GUSSET IS GOUGED FROM FRAME 20 TO 22. UPPER SURFACE IS CORRODED AROUND FASTENERS. REMOVED AND REPLACED GUSSET IAW EMB 135 SRM 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.