What was found
ABI - DURING INSPECTION FOUND STRINGER 19L CHAFED AT FRAME 53. BLENDED CHAFE. FABRICATED AND INSTALLED DOUBLER ANGLE, WITH TWO SHIMS IAW EMB 145 (145/1142, CHAPTER 53, REV 18) 532-24-02, ETN EM-51-020, AND STANDARD SRM PRACTICES. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ABI - DURING INSPECTION FOUND STRINGER 19L CHAFED AT FRAME 53. BLENDED CHAFE. FABRICATED AND INSTALLED DOUBLER ANGLE, WITH TWO SHIMS IAW EMB 145 (145/1142, CHAPTER 53, REV 18) 532-24-02, ETN EM-51-020, AND STANDARD SRM PRACTICES. (M)