DURING AN IMBV INSPECTION FOUND STRINGER 19L CHAFED BETWEEN FRAMES 52 AND 53. BLENDED CHAFE. PERFORMED NDT INSPECTION NO DEFECTS. FABRICATED A DOUBLER ANGLER, AND TWO SHIMS. REPAIR DONE IAW STANDARD SRM PRACTICES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING AN IMBV INSPECTION FOUND STRINGER 19L CHAFED BETWEEN FRAMES 52 AND 53. BLENDED CHAFE. PERFORMED NDT INSPECTION NO DEFECTS. FABRICATED A DOUBLER ANGLER, AND TWO SHIMS. REPAIR DONE IAW STANDARD SRM PRACTICES.