What was found
ABI - FOUND ONE DENT AFT OF PASSENGER DOOR ON EMB PLACARD AT FRAME 19 AND 20 AND STRINGER 14L AND 15L. PERFORMED NDT, NO DEFECTS, DENT ACCEPTED AS IS IAW EMB GST-1999/02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ABI - FOUND ONE DENT AFT OF PASSENGER DOOR ON EMB PLACARD AT FRAME 19 AND 20 AND STRINGER 14L AND 15L. PERFORMED NDT, NO DEFECTS, DENT ACCEPTED AS IS IAW EMB GST-1999/02. (M)