As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING MBV INSPECTION MAINTENANCE FOUND FRAME IN CARGO BAY DENTED AT STATION 686.888. DENT WAS RECONTOURED AND AN NDT INSPECTION WAS COMPLIED WITH NO DEFECTS WERE NOTED. A REPAIR DOUBLER WAS INSTALLED IAW REPAIR STATEMENT AND STANDARD PRACTICES.