What was found
FOUND NUMEROUS UNDOCUMENTED BLENDED AREAS ON SERVICE DOOR CENTER SILL. FILLED BLENDED AREAS WITH EPOXY RESIN, SANDED AREA SMOOTH. FABRICATED REPAIR DOUBLER. REPAIR DONE IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND NUMEROUS UNDOCUMENTED BLENDED AREAS ON SERVICE DOOR CENTER SILL. FILLED BLENDED AREAS WITH EPOXY RESIN, SANDED AREA SMOOTH. FABRICATED REPAIR DOUBLER. REPAIR DONE IAW SRM.