What was found
ABI - THIS IS A LEVEL 2 FINDING, GALLEY AREA CENTER BEAM HAS CORROSION. INSTALLED REPAIR DOUBLER AND FILLER IAW EMB GST-1736/02C AND ETN EM 53-034R1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ABI - THIS IS A LEVEL 2 FINDING, GALLEY AREA CENTER BEAM HAS CORROSION. INSTALLED REPAIR DOUBLER AND FILLER IAW EMB GST-1736/02C AND ETN EM 53-034R1. (M)