ABI - DURING IMBV INSPECTION, STRINGER 19L WAS FOUND TO BE CHAFED AT SKIN JUNCTION 05. BLENDED CHAFED AREA. PERFORMED EDDY CURRENT INSPECTION WITH NO DEFECTS NOTED. FABRICATED A DOUBLER ANGLE, TWO SHIMS. REPAIR DONE IAW EMB 145 SRM (145/1142, CHAPTER 53, REV 19, 53-24-02 AND STANDARD SRM PRACTICES. (M)