ABI - DURING AN MBV INSPECTION, STRINGER 19R WAS FOUND TO BE CHAFED AT JUNCTION 05. BLENDED CHAFED AREA. PERFORMED EDDY CURRENT INSPECTION NO DEFECTS NOTED. FABRICATED A DOUBLER ANGLE, TWO SHIMS. REPAIR DONE IAW EMB 145 SRM (145/1142, CHAPTER 53, REV 19) 53-24-02, AND STANDARD SRM PRACTICES. (M)