What was found
ABI - A LEVEL 2 FINDING WAS FOUND DURING IMBV INSPECTION REFERENCE CRIC NR 28017 SERVICE DOOR CENTER SILL CORRODED. SERVICE DOOR CENTER SILL REPAIRED IAW EMB 145 ETN EM-53-036, GST-1927/02A, SRM 51-40-02, 51-20-03, 51-40-06. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ABI - A LEVEL 2 FINDING WAS FOUND DURING IMBV INSPECTION REFERENCE CRIC NR 28017 SERVICE DOOR CENTER SILL CORRODED. SERVICE DOOR CENTER SILL REPAIRED IAW EMB 145 ETN EM-53-036, GST-1927/02A, SRM 51-40-02, 51-20-03, 51-40-06. (M)