What was found
ABI - DURING AN MBV INSPECTION, STRINGER 19L WAS FOUND TO BE CHAFED AT SKIN JUNCTION 05. BLENDED CHAFED AREA. PERFORMED EDDY CURRENT INSPECTION OF THE AREA. NO DEFECTS NOTED. FABRICATED AND A DOUBLER ANGLE, TWO SHIMS. REPAIR DONE IAW EMB 145 SRM (145/1142 REV 20) 53-24-02, AND STANDARD SRM PRACTICES. (M)