What was found
ABI - DURING A MBV INSPECTION, TWO DENTS WERE FOND BETWEEN SKIN JUNCTION 07 AND FRAME 77, STRINGER 18R AND 19R. REMOVED BOTH DENTS WITH SINGLE CUTOUT. FABRICATED A REPAIR DOUBLER AND FILLER. REPAIR DONE IAW EMB 145 SRM (145/1142 REV 20) 53-32-01, TYPE A, FIG 201 AND STANDARD SRM PRACTICES. (M)