As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ABI - DURING A IMBV INSPECTION, THE SERVICE DOOR CENTER SILL WAS FOUND TO BE CORRODED BELOW SRM LIMITS. BLENDED THE CORRODED AREA OF THE CENTER SILL AND PERFORMED AN NDT INSPECTION. FABRICATED A DOUBLER, REPAIR DONE IAW EMB SRM (SRM 145/1142 REV 20) CHAPTER 51-21-02 AND EMB REPAIR STATEMENT 1C2003-145/0771. (M)