What was found
THIS IS A LEVEL TWO FINDING FOUND DURING A IMBV INSPECTION, RIGHT BEAM GUSSET AT FRAME 20 IS CORRODED. REMOVED AND INSTALLED NEW RIGHT BEAM GUSSET AT FRAME 20 IAW EMB 135 SRM 51-20-03, 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THIS IS A LEVEL TWO FINDING FOUND DURING A IMBV INSPECTION, RIGHT BEAM GUSSET AT FRAME 20 IS CORRODED. REMOVED AND INSTALLED NEW RIGHT BEAM GUSSET AT FRAME 20 IAW EMB 135 SRM 51-20-03, 51-40-02. (M)