What was found
THIS IS A LEVEL TWO FINDING, FOUND DURING AN IMBV INSPECTION SERVICE DOOR FORWARD SILL IS CORRODED. REMOVED AND INSTALLED SERVICE DOOR SILL IAW EMB 135 SRM 51-40-02, 51-20-03 AND 51-40-06. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THIS IS A LEVEL TWO FINDING, FOUND DURING AN IMBV INSPECTION SERVICE DOOR FORWARD SILL IS CORRODED. REMOVED AND INSTALLED SERVICE DOOR SILL IAW EMB 135 SRM 51-40-02, 51-20-03 AND 51-40-06. (M)