What was found
THIS IS A LEVEL TWO FINDING FOUND DURING A MBV INSPECTION, GALLEY FORWARD DIAMOND GUSSET CORRODED. INSTALLED NEW DIAMOND GUSSET IN GALLERY AREA IAW EMB 140 SRM 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THIS IS A LEVEL TWO FINDING FOUND DURING A MBV INSPECTION, GALLEY FORWARD DIAMOND GUSSET CORRODED. INSTALLED NEW DIAMOND GUSSET IN GALLERY AREA IAW EMB 140 SRM 51-40-02. (M)