What was found
ABI - DUIRNG A MBV INSPECTION, STRINGER 19L AT FRAME 53 WAS FOUND CHAFED BELOW SRM LIMITS. BLENDED THE CHAFED AREA AND PERFORMED AN NDT INSPECTION WITH NO REJECTABLE INDICATIONS. FABRICATED A REPAIR ANGLE AND SHIMS. REPAIR DONE IAW EMB SRM, SRM 145/1142 REV 21, CHAPTERS 53-24-02 FIGURE 201. (M)