What was found
THIS IS A LEVEL TWO FINDING FOUND DURING AN MBV INSPECTION, CENTER BEAM RAMP IS CORRODED AT FRAME 20. REMOVED CORRODED CENTER BEAM RAMP AND INSTALLED NEW SERVICEABLE RAMP IAW EMB 140 SRM 51-40-02, 51-20-03. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THIS IS A LEVEL TWO FINDING FOUND DURING AN MBV INSPECTION, CENTER BEAM RAMP IS CORRODED AT FRAME 20. REMOVED CORRODED CENTER BEAM RAMP AND INSTALLED NEW SERVICEABLE RAMP IAW EMB 140 SRM 51-40-02, 51-20-03. (M)