What was found
ABI - THIS IS A LEVEL 2 FINDING FOUND DURING AN IMBV INSPECTION, GALLEY CROSSBEAM (P/N 145-29150-001) AND PROFILE (P/N 145-29150-003) HAVE CORROSION. INSTALLED SERVICEABLE CROSSBEAM AND PROFILE IAW EMB 145 SRM 51-40-06, 51-20-03 AND 51-40-02. (M)