What was found
ABI - THIS A LEVEL TWO FINDING FOUND DURNG AN IMBV INSPECTION, RIGHT OMEGA BEAM 1/2 DIAMOND GUSSET AT FRAME 23 CORRODED. REMOVED AND INSTALLED RIGHT FLOORBEAM GUSSET AT FRAME 23 IAW EMB 145 SRM 51-20-01/03, 51-40-02/04/06. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ABI - THIS A LEVEL TWO FINDING FOUND DURNG AN IMBV INSPECTION, RIGHT OMEGA BEAM 1/2 DIAMOND GUSSET AT FRAME 23 CORRODED. REMOVED AND INSTALLED RIGHT FLOORBEAM GUSSET AT FRAME 23 IAW EMB 145 SRM 51-20-01/03, 51-40-02/04/06. (M)