What was found
THIS IS A LEVEL 2 FINDING, FOUND DURING AN IMBV INSPECTION GALLEY CENTER BEAM RAMP CORRODED. REMOVED AND REPLACED CENTER GALLEY BEAM IAW EMB 135 SRM 51-40-2/04, 51-20-03. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THIS IS A LEVEL 2 FINDING, FOUND DURING AN IMBV INSPECTION GALLEY CENTER BEAM RAMP CORRODED. REMOVED AND REPLACED CENTER GALLEY BEAM IAW EMB 135 SRM 51-40-2/04, 51-20-03. (M)