What was found
THIS IS A LEVEL 2 FINDING, FOUND DURING AN IMBV INSPECTION SERVICE DOOR FORWARD SILL CORRODED. REMOVED AND INSTALLED SERVICEABLE SILL IAW EMB SRM 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THIS IS A LEVEL 2 FINDING, FOUND DURING AN IMBV INSPECTION SERVICE DOOR FORWARD SILL CORRODED. REMOVED AND INSTALLED SERVICEABLE SILL IAW EMB SRM 51-40-02. (M)