What was found
ABI - DURING AN IMBV INSPECTION, THE SHEAR TIE AT FRAME 68 AND THE CARGO DOOR CUTOUT WAS FOUND TO BE CORRODED BEYOND SRM LIMITS. REMOVED CORROSION BY PERFORMING AN CUT OUT OF THE LOWER PORTION OF THE SHEAR TIE. FABRICATED A REPLACEMENT SPLICE. REPAIR DONE IAW EMB REPAIR STATEMENT IC2003-145/1615 AND STANDARD EMB SRM, SRM 145/1142 REV 21, PRACTICES. (M)