What was found
ABI - DURING AN MBV, THE CENTER FLOORBEAM LOEWR FLANGE WAS FOUND TO BE CORRODED BEYOND SRM LIMITS BETWEEN FRAME 24 AND 25. BLENDED THE DAMGED AREA TO REMOVE ALL CORROSION. PERFORMED AN EDDY CURRENT INSPECTION OF THE BLENDED AREA WITH NO DEFECTS NOTED. FABRICATED A REINFORCEMENT DOUBLER. REPAIR DONE IAW EMB STATEMENT IC2003-145/1766, EMB SRM 145/1142 REV 21, 53-21-10 PARA 9, FIG 208 AND STANDARD SRM PRACTICES. (M)