What was found
ABI - DURING AN MBV INSPECTION, FOUND STRINGER 19R CHAFED AT FRAME 53. BLENDED THE CAHFED AREA AND PERFORMED NDT INSPECTION NO DEFECTS NOTED. FABRICATED A REPAIR ANGLE AND SHIMS AND INSTALLED. REPAIR DONE IAW EMB SRM, SRM EMB 145/1142 REV 21, CHAPTER 53-24-02 FIGURE 201. RESTORED SURFACE FINISH TO THE REPAIR AREA. (M)