What was found
ABI - DURING AN IMBV INSPECTION, THE FORWARD DIGITAL WAS FOUND TO BE CORRODED BELOW SRM LIMITS. BLENDED THE CORRODED AREA AND PERFORMED NDT INSPECTION. APPLIED TREATMENT TO THE BARE METAL SURFACE. FABRICATED A REPAIR DOUBLER, REPAIR DONE IAW EMB REPAIR STATEMENT IC 2003-145/2467A DATED JULY 22, 2003. (M)