What was found
ABI - DURING AN MBN INSPECTION, FOUND STRINGER 19R WAS FOUND CHAFED BELOW SRM LIMITS. BLENDED THE CHAFED ARE AND PERFORMED NDT INSPECTION. FABRICATED A REPAIR ANGLE, SHIMS. REPAIR DONE IAW EMB 145 SRM, SRM EMB 145/1142 REV 22, CHAPTER 53-24-02. (M)