What was found
ABI - DURING AN MBV INSPECTION, STRINGER 19L WAS FOUND CHAFED BELOW SRM LIMITS. BLENDED THE CHAFED AREA AND PERFORMED NDT INSPECTION. FABRICATED A REPAIR ANGLE AND SHIMS. REPAIR DONE IAW EMB 145 SRM, SRM 145/1142 REV 22, CHAPTERS 53-24-02. (M)