What was found
ABI - DURING AN IMBV INSPECTION, FOUND STRINGER 19R WAS FOUND TO BE CHAFED BEYOND SRM LIMITS AFT OF FRAME 52. COMPLETELY REMOVED CHAFE BLENDING AREA. PERFORMED AN EDDY CURRENT INSPECTION OF THE BLENDED AREA. NO DEFECTS NOTED. FABRICATED ONE REPAIR ANGLE, TWO SHIMS. REPAIR DONE IAW EMB REPAIR STATEMENT IC2003-145/2633, IC2003-145/2718A AND STANDARD EMB SRM PRACTICES. (M)