As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ABI - FOUND DURING AN IMBV INSPECTION, THE CENTER OMEGA BEAM BETWEEN FRAMES 24 AND 25 WAS FOUND CORRODED BELOW SRM LIMITS. BLENDED THE CORRODED AREA AND PERFORMED NDT INSPECTION. FABRICATED A REPAIR DOUBLER. REPAIR DONE IAW EMB REPAIR STATEMENT IC2003-145/2779. (M)