What was found
ABI - DURING A MBV INSPECTION, FOUND STRINGER 19L WAS FOUND TO BE CHAFED BELOW SRM LIMITS. BLENDED THE CHAFED AREA AND PERFORMED NDT INSPECTION. FABRICATED A REPAIR ANGLE AND TWO SHIMS. REPAIR DONE IAW EMB 145 SRM, SRM EMB 145/1142 REV 22, CHAPTER 53-24-02 FIGURE 201. (M)