What was found
ABI - DURING A MBV INSPECTION, FOUND STRINGER 19L WAS FOUND CHAFED BELOW SRM LIMITS. BLENDED THE CHAFED AREA AND PERFORMED NDT INSPECTION. FABRICATED REPAIR ANGLE AND TWO SHIMS. REPAIR DONE IAW EMB SRM, SRM 145/1142, REV 22, CHAPTER 53-24-02 AND EMB IC2003-145/3093A. (M)