What was found
ABI - DURING AN MBV INSPECTION, FOUND STRINGER 19R WAS FOUND CHAFED BELOW SRM LIMITS. BLENDED THE CHAFED AREA AND PERFORMED NDT INSPECTION. FABRICATED A REPAIR ANGLE AND TWO SHIMS. REPAIR DONE IAW EMB 145 SRM, SRM EMB-145/1142 REV 22, CHAPTERS 53-24-02 AND EMB IC2003-145/3093A. (M)