What was found
ABI - DURING AN MBV INSPECTION, FOUND STRINGER 19L WAS FOUND CHAFED BELOW SRM LIMITS BETWEEN FRAMES 52 AND 53. BLENDED THE CHAFED AREA AND PERFORMED AN EDDY CURRENT INSPECTION WITH NO DEFECTS NOTED. FABRICATED A REPAIR ANGLE AND SHIMS FOR REPAIR. REPAIR DONE IAW EMB 145 SRM, SRM EMB 145/1142 REV 22, CHAPTER 53-24-02, EMB STATEMENT IC2003-145/3098A AND STANDARD SRM PRACTICES. (M)