What was found
ABI - DURING A IMBV INSPECTION, THE RIGHT PROFILE AFT OF FRAME 18 WAS FOUND CORRODED BELOW LIMITS AROUND NUT PLATE. CUT OUT SECTION OF CORRODED PROFILE, PERFORMED NDT INSPECTION AND TREATED BARE METAL. FABRIATED A REPAIR ANGLE. REPAIR DONE IAW EMB REPAIR STATEMENT IC2003-145/3289 DATED NOV 17, 2003. (M)